The re vent is the only exception since it runs horizontally.
Roof vent pipe height.
The vent stack is the pipe leading to the main roof vent.
Above the roof plumbing vent height.
All open vent pipes that extend through a roof shall be terminated at least number typically 6 inches mm above the roof except that where a roof is to be used for any purpose other than weather protection the vent extensions shall be run at least 7 feet 2134 mm above the roof.
However it needs to be at least six inches above your fixture s flood level to keep from getting wet.
If the roof area is for people then it is 7 ft above the roofing surface.
On a sink that would be either the rim or overflow hole.
Its drainage and vent functions are actually two systems.
Why plumbing air vents are important.
Your home s plumbing system is designed to efficiently remove water and waste.
It channels the exhaust gases to the vent and helps maintain proper atmospheric pressure in the waste system.
Vents exceeding 40 feet 12 192 mm in developed length shall be increased by one nominal pipe size for the entire developed length of the vent pipe.
If the pipe is farther than 10 feet from the roof peak it must be 2 feet above the highest point of the roof within 10 feet.
A note on the main drain.
Vent pipes shall not be less than 1 1 4 inches 32 mm in diameter.
The required size of the drain shall be determined in accordance with table 710 1 2.
Vent pipes should extend to outdoors above the building roof and should terminate vertically not less than 6 above the roof surface nor more than 24 and must be at least 12 from any vertical surface such as a nearby sidewall.
A vent terminal and depending if the roof is strictly for weather protection it terminates about 24 above the roof.